The core function of cooling in a test chamber is to dissipate heat and regulate temperature, ensuring stable operation of key components such as the compressor. The two common cooling methods are air cooling and water cooling , which differ significantly in heat transfer medium, application scenarios, advantages, and limitations. A detailed analysis is provided below.
I. Air Cooling
1. Core Principle
Heat is dissipated through air circulation. Fans drive ambient air flow to remove heat generated by the compressor and refrigeration system, using air directly as the cooling medium without additional media.
2.Application Conditions
Optimal cooling efficiency is achieved when the ambient operating temperature is maintained at “25±5℃”, the range where air heat exchange efficiency peaks.
3.Key Advantages
l Low maintenance cost & convenience: No auxiliary equipment required; only regular cleaning of fans and filters is needed, with no piping or cooling tower maintenance.
l Suitable for northern China climates: Northern regions have consistently low temperatures, easily meeting the 25±5℃ requirement for stable heat dissipation, making it the mainstream choice.
l Flexible installation: No complex piping; plug-and-use operation with no obstacles to relocation or site adjustment.
4.Main Disadvantages
l Highly ambient temperature-dependent: In high ambient temperatures (e.g., summer heat, enclosed spaces), air heat exchange efficiency drops sharply, severely reducing cooling performance.
l Impacts equipment lifespan: Compressors operate under high load in high temperatures, shortening service life with prolonged use.
l Slow cooling speed: Air has low specific heat capacity, resulting in lower heat transfer efficiency than water and slower cooling under identical conditions.
II. Water Cooling
1. Core Principle
Water serves as the cooling medium, leveraging its fluidity and high specific heat capacity. Circulating water absorbs heat from the refrigeration system, which is then released via external devices (cooling tower, chiller) for continuous heat dissipation.
2.Supporting Requirements
Requires additional installation of a cooling tower, water pump, dedicated circulation piping, or integration with a standalone chiller to form a complete water circulation cooling system.
3.Key Advantages
l Ambient temperature-independent : Stable heat dissipation regardless of high temperatures or enclosed spaces, with strong adaptability.
l High heat dissipation efficiency & fast cooling : Water’s far higher specific heat capacity enables rapid heat transfer and temperature reduction.
l Extended equipment lifespan : Compressors run efficiently under low load, significantly prolonging service life.
l Suitable for southern China climates : Southern regions experience hot, humid summers where air cooling is easily compromised, making water cooling the preferred option.
4.Main Disadvantages
l High upfront investment : Additional costs for purchasing cooling towers, pumps, pipes, and related installation and materials.
l Complex installation & relocation : Piping layout requires advance planning; fixed sites are difficult to relocate or modify.
l Ongoing maintenance needs : Regular water quality checks and pipe scale removal are necessary to prevent clogging and maintain circulation efficiency.
III. Core Summary of Air Cooling vs. Water Cooling
l Identical core purpose : Both methods cool test chambers by dissipating heat, differing only in cooling medium (air/water) and heat transfer path.
l No absolute superiority : Selection depends primarily on test site environment, climate conditions, and equipment configuration, not inherent merit.
l Critical selection rule : Air cooling is prohibited for compressors above 6HP ; water cooling is mandatory to ensure heat dissipation efficiency and equipment safety.
IV. Summary
In short, choose air cooling for low-temperature northern environments, low-power units, and ease of maintenance; select water cooling for high-temperature southern environments, high-power units, and high-efficiency heat dissipation.
For enterprises in manufacturing, electronic technology, and related industries, product reliability testing is a critical quality assurance link. However, the operational costs of environmental test chambers—core testing equipment—are often overlooked. Many businesses focus solely on testing precision during procurement, only to be troubled by high energy bills in long-term use. Our energy-saving environmental test chamber effectively resolves the conflict between "accurate testing" and "cost control," providing comprehensive support for product lifecycle cost management.
Core Energy-Saving Feature: Intelligent Refrigeration System Regulation
As the primary energy-consuming component of environmental test chambers, the energy regulation technology of the refrigeration system directly determines the equipment’s energy efficiency. On the premise of meeting core technical indicators, this test chamber innovatively integrates multiple energy adjustment measures to achieve intelligent dynamic control of refrigeration capacity.
The system precisely regulates evaporation temperature via the controller and links it with a hot gas bypass energy adjustment mechanism, matching refrigeration demand in real time based on the required cooling rate and target temperature range. When approaching the set low temperature, the system automatically reduces refrigeration capacity to avoid temperature overshoot—a common issue in traditional models—ensuring test stability. During the constant temperature phase, it abandons the energy-intensive "hot-cold balance" mode, optimizing energy utilization at the source. Verified in real operating conditions, the energy-saving effect reaches up to 30%, significantly reducing long-term operational costs, especially for enterprises requiring 24/7 continuous operation.
Precision & Energy Efficiency: Optimized Heating System Power Control
Refined control of the heating system further enhances the equipment’s energy-saving advantages and temperature control precision. The system adopts a synergistic control scheme of temperature controllers and thyristors: the temperature controller collects real-time temperature signals and issues control commands, while thyristors precisely adjust the heater’s power output.
When the temperature is far below the set value, thyristors deliver full power for rapid heating. As the temperature gradually approaches the set value, the output power decreases incrementally; once the target temperature is reached, power output stops immediately. This on-demand power distribution mode eliminates energy waste and ensures precise temperature control, providing a stable and reliable temperature environment for tests.
For example: When the internal temperature is significantly lower than the set value, thyristors operate at full power, and the heater runs at maximum load to ensure rapid temperature rise. As the temperature nears the target, the thyristor’s output power gradually decreases. Once the target temperature is achieved, the thyristor stops power output immediately, and the heater enters standby mode. This "on-demand power supply" mode eliminates the drawback of "frequent start-stop" in traditional heating systems—avoiding ineffective energy consumption while greatly improving temperature control precision, making it particularly suitable for test scenarios requiring high temperature stability.
Dual-System Synergy: Safeguard Enterprise Costs
From the refrigeration system’s intelligent energy adjustment to the heating system’s precision power control, our environmental test chamber centers on dual-system collaborative energy-saving technology. While ensuring accurate test data, it maximizes energy cost reduction. Choosing our test chamber not only guarantees product testing quality but also enables scientific management of enterprise operational costs, providing peace of mind throughout your product R&D and production processes.
In addition, if your enterprise is seeking a cost-effective environmental test chamber or struggling with high energy consumption from existing equipment, we recommend focusing on our energy-saving model. Let professional equipment protect your product quality while reducing costs and enhancing efficiency for your business.
I. Receipt Inspection
1. Physical Verification
Confirm equipment model, specifications, and serial number match the contract/packing list to avoid wrong delivery.
Inspect the cabinet, door, and control panel for transportation damage (dents, deformation) and ensure pipelines/wiring are intact without loosening.
2. Accessory & Document Check
Required accessories: Power cord, sample shelves, sealing rings, wrenches, and other tools (verify against the packing list).
Technical documents: Operation/maintenance manual, calibration certificate, warranty card, and qualification certificate (all mandatory for after-sales service).
3. Abnormal Handling
In case of damage or missing items: Immediately take photos (overall equipment, damaged details, packing list), notify the supplier within 24 hours to submit a claim, and sign the "Acceptance Objection Form" for documentation.
II. Installation & Deployment (Compliant Installation Ensures Performance)
1. Environment Requirements (Must Meet the Following)
Floor: Flat and sturdy, with load-bearing capacity ≥1.2 times the equipment weight (to avoid test errors caused by vibration).
Space: ≥30cm ventilation gap around the cabinet; keep away from heat sources, water sources, dust, and strong electromagnetic interference.
Power supply: Match the rated voltage (e.g., 380V three-phase five-wire/220V single-phase), grounding resistance ≤4Ω, and equip an independent air switch (power ≥1.2 times the equipment's rated power).
Environment: Room temperature 15-35℃, humidity ≤85%RH (no condensation); water-cooled models require pre-connected cooling water circuits meeting specifications.
2. Basic Installation Steps
Level the equipment: Adjust anchor bolts and use a level to confirm horizontal alignment (to prevent uneven stress on the refrigeration system).
Wiring inspection: Connect the power supply per the manual and ensure correct neutral/grounding connections (a common cause of electrical failures).
Consumable check: Confirm refrigerant and lubricating oil (if applicable) are properly filled with no leakage.
III. Commissioning (Core: Verify Performance Compliance)
1. First Startup Procedure
(1) Recheck power/pipeline connections before power-on; switch on after confirmation.
(2)Panel self-test: Ensure the display shows no error codes and buttons/indicators function normally.
(3)No-load operation (2-4 hours):
Set a common temperature range (e.g., -40℃~85℃) and monitor temperature fluctuation ≤±0.5℃ (meets industrial standards).
Check door sealing (no obvious air leakage), operating noise ≤75dB, and normal start/stop of refrigeration/heating systems.
2. Load Verification (Simulate Actual Usage)
Place a load equivalent to the test sample (weight/volume ≤80% of the equipment's rated load) without blocking air ducts.
Set the target temperature and holding time; record if the heating/cooling rate meets technical parameters (e.g., -40℃~85℃ heating time ≤60 minutes).
Alarm test: Simulate power failure, over-temperature, or door-open timeout to confirm timely alarm response (audio-visual alarm + shutdown protection).
IV. Emergency Handling & After-Sales Coordination
1. Common Fault Resolution
Error codes: Refer to the "Troubleshooting" section in the manual (e.g., E1=Over-temperature, E2=Power abnormality).
Sudden failures: (e.g., electric leakage, abnormal noise, refrigeration failure) Immediately cut off power, stop use, and contact the supplier's technical support (do not disassemble independently).
2. After-Sales Support
Retain the supplier's after-sales contact (phone + email) and confirm the warranty period (usually 1 year for the whole machine).
Maintenance records: Request a "Maintenance Report" after each service and file it for future tracing.
Phòng thử nhiệt độ Walk-in là một phòng thí nghiệm lớn cho phép người vận hành đi vào, chủ yếu được sử dụng để thử nghiệm môi trường. Nó thường được sử dụng để thử nghiệm các bộ phận lớn, sản phẩm bán thành phẩm và sản phẩm hoàn thiện để mô phỏng nhiệt độ môi trường thực tế và được sử dụng rộng rãi trong các ngành công nghiệp như kỹ thuật điện, thiết bị điện, dụng cụ, điện tử, an ninh, truyền thông, cảm biến, tự động hóa, điều khiển công nghiệp, máy móc chính xác, v.v. Buồng thử nhiệt độ đi vào được trang bị lỗ thử φ 50mm có phích cắm ở bên hông hộp. Vật liệu phích cắm là cao su silicon ít bọt, có thể chịu được nhiệt độ cao và thấp và có tác dụng cách nhiệt. Máy sưởi sử dụng máy sưởi điện dây niken crom khung sứ, có quán tính nhiệt thấp và tuổi thọ cao. Thiết bị đưa ra tín hiệu PID chu kỳ xung có thể điều khiển được, được điều khiển bởi rơle trạng thái rắn để điều khiển mượt mà hơn và đáng tin cậy hơn.
Hiệu suất và đặc điểm của Buồng thử nhiệt độ Walk-in:
1. Có phạm vi kiểm soát nhiệt độ và độ ẩm cực kỳ rộng, có thể đáp ứng nhiều nhu cầu khác nhau của người dùng. Bằng cách áp dụng phương pháp kiểm soát nhiệt độ và độ ẩm cân bằng độc đáo, có thể đạt được môi trường nhiệt độ và độ ẩm an toàn và chính xác. Có hiệu suất làm nóng và tạo ẩm ổn định và cân bằng, có thể đạt được khả năng kiểm soát nhiệt độ và độ ẩm có độ chính xác cao.
2. Được trang bị bộ điều chỉnh nhiệt độ thông minh, nhiệt độ và độ ẩm được hiển thị bằng màn hình kỹ thuật số LED. Buồng thử nhiệt ẩm nhiệt độ cao và thấp có thể được trang bị tùy chọn máy ghi nhiệt độ và độ ẩm.
3. Tự động lựa chọn mạch làm lạnh, thiết bị điều khiển tự động có chức năng tự động lựa chọn và vận hành mạch làm lạnh theo giá trị nhiệt độ cài đặt, thực hiện khởi động trực tiếp máy làm lạnh và làm lạnh trực tiếp trong điều kiện nhiệt độ cao.
4. Cửa bên trong được trang bị cửa sổ quan sát lớn, giúp quan sát dễ dàng trạng thái thực nghiệm của các mẫu thử.
5. Được trang bị các thiết bị an toàn và bảo vệ tiên tiến - cầu dao chống dòng điện dư, bộ bảo vệ quá nhiệt, bộ bảo vệ mất pha và bộ bảo vệ ngắt nước.
Chúng tôi có thể cung cấp Buồng thử nhiệt độ cao và thấp, buồng thử nhiệt độ thấp, buồng thử nhiệt độ và độ ẩm không đổi, buồng thử nhiệt ẩm nhiệt độ cao và thấp, buồng thử nhiệt ẩm xen kẽ nhiệt độ cao và thấp, buồng thử ăn mòn phun muối. Các buồng thử trên có thể được tùy chỉnh theo yêu cầu của bạn.
Do đó, Buồng thử nhiệt độ di động phù hợp với các doanh nghiệp có nhu cầu cao về thử nghiệm môi trường và không gian hoạt động.
Nếu bạn quan tâm đến sản phẩm của chúng tôi và muốn biết thêm thông tin chi tiết, vui lòng để lại tin nhắn ở đây, chúng tôi sẽ trả lời bạn sớm nhất có thể.